Approach to a water safety plan for recreational waters: disinfection of a drainage pumping station as an unconventional point source of fecal contam…

2020

Abstract In the context of the management of bathing water quality, the intermittent contamination of rainwater drainage pumps (unconventional point sources) could be controlled by peracetic acid disinfection. Thus, a field experimental study was carried out to set up a water safety plan, determining the monitoring parameters and the critical limit for corrective actions. With a 0.5 mg/l dosage, the average logarithmic microbial reduction was 0.50 ± 0.48 for Escherichia coli (EC) and 0.43 ± 0.54 for intestinal enterococci. Among the chemical and physical parameters that could be monitored in real time, the oxidation–reduction potential was the only one able to predict the microbial concentr…

010504 meteorology & atmospheric sciencesPoint source0208 environmental biotechnologybathing waters; qualitative microbial risk assessment (QMRA); unconventional point sources; water safety planEnvironmental engineering02 engineering and technologyManagement Monitoring Policy and LawEnvironmental Science (miscellaneous)01 natural sciencesunconventional point sources020801 environmental engineeringFecal coliformwater safety planWater safety planEnvironmental scienceDrainageRecreationbathing waters0105 earth and related environmental sciencesWater Science and Technologyqualitative microbial risk assessment (QMRA)
researchProduct